Does an Infrared Sauna Need a Dedicated Circuit?

Last updated 2026-10-07

Of the 97 infrared saunas in the InHouse Wellness Verified Sauna Database whose manufacturer states an electrical requirement, 38 say a dedicated circuit is required, 24 call for a dedicated outlet or circuit without saying "required", 13 recommend one, and 22 do not mention a dedicated circuit.

Each row quotes the manufacturer's own words. A recommendation is not a requirement, and the two are counted separately.

Model What the manufacturer states about the circuit Grade · source · verified
Almost Heaven Hinton Infrared Sauna, 2–3 Person …“Hardware : 120V, 20 amp dedicated outlet”… Listed · manufacturer page · 2026-09-28
Almost Heaven Laurel Infrared Sauna, 1 Person …“Hardware : 120V, 20 amp dedicated outlet”… Listed · manufacturer page · 2026-09-28
Clearlight Premier 2, 2 Person …“Electrical Components 120 Volts 1,720 Watts 14.5 Amps Plugs into a standard household outlet.”… Listed · manufacturer page · 2026-09-28
Clearlight Premier 3, 3 Person …“Electrical Components 120 Volts 2,050 Watts 17.1 Amps Plugs into a 120V / 20 Amp outlet.”… Listed · manufacturer page · 2026-09-28
Clearlight Sanctuary 2 Infrared Sauna, 2 Person …“your calves, and under the floor Electrical Components 120 Volts 2,260 Watts 18.83 Amps Plugs into a 120V / 20 Amp outlet.”… Listed · manufacturer page · 2026-09-28
Clearlight Sanctuary 3 Infrared Sauna, 3 Person …“Electrical Components 240 Volts 2,680 Watts 11.7 Amps Plugs into a 240V outlet”… Listed · manufacturer page · 2026-09-28
Clearlight Sanctuary C Infrared Sauna, 4 Person …“your calves, and under the floor Electrical Components 240 Volts 3,330 Watts 13.9 Amps Plugs into a 240V outlet”… Listed · manufacturer page · 2026-09-28
Clearlight Sanctuary Retreat Infrared Sauna, 4–5 Person …“Electrical Components 240 Volts 3,570 Watts 14.9 Amps Plugs into a 240V outlet”… Listed · manufacturer page · 2026-09-28
Dynamic Saunas Avila Far IR Sauna, 1–2 Person, DYN-6103-01 …“Electrical service: 120V/15amp Non GFCI plug & play (Recommended Dedicated Outlet)”… Listed · manufacturer page · 2026-10-07
Dynamic Saunas Avila Far IR Sauna, 1–2 Person, DYN-6103-01 Elite …“Electrical service: 120V/15amp Non GFCI plug & play (Recommended Dedicated Outlet)”… Listed · manufacturer page · 2026-10-07
Dynamic Saunas Barcelona Elite Far IR Sauna, 1–2 Person …“Electrical service: 120V/15amp Non GFCI plug & play (Recommended Dedicated Outlet)”… Listed · manufacturer page · 2026-10-07
Dynamic Saunas Barcelona Far IR Sauna, 1–2 Person …“Electrical service: 120V/15amp Non GFCI plug & play (Recommended Dedicated Outlet)”… Listed · manufacturer page · 2026-10-07
Dynamic Saunas Bellagio Far IR Sauna, 3 Person …“Electrical service: Special Electrical 120 V/20 AMP Non GFCI Dedicated Receptacle and breaker”… Listed · manufacturer page · 2026-10-07
Dynamic Saunas Bergamo Far IR Sauna, 4 Person “CARBON MODEL SAUNA FOR INDOOR USE ONLY 120VAC 20AMP Dedicated Circuit Required”… Documented · manual, p. 1 · 2026-09-28
Dynamic Saunas Cordoba Far IR Sauna, 2 Person …“Electrical service: 120V/15amp Non GFCI plug & play (Recommended Dedicated Outlet)”… Listed · manufacturer page · 2026-10-07
Dynamic Saunas Cordoba Full Spectrum IR Sauna, 2 Person “Manual INFRARED MODEL SAUNA SAUNA IS FOR INDOOR USE ONLY 120VAC 15AMP Dedicated Circuit Required”… Documented · manual, p. 1 · 2026-09-28
Dynamic Saunas Cordoba, 2 Person …“Electrical service: 120V/15amp Non GFCI plug & play (Recommended Dedicated Outlet)”… Listed · manufacturer page · 2026-10-07
Dynamic Saunas Gracia Far IR Sauna, 1–2 Person, DYN-6119-01 “CARBON MODEL SAUNA FOR INDOOR USE ONLY 120VAC 15AMP Dedicated Circuit Required”… Documented · manual, p. 1 · 2026-09-28
Dynamic Saunas Gracia Far IR Sauna, 1–2 Person, DYN-6119-01 Elite “ULTRA LOW EMF CARBON MODEL SAUNA FOR INDOOR USE ONLY 120VAC 15AMP Dedicated Circuit Required”… Documented · manual, p. 1 · 2026-09-28
Dynamic Saunas Gracia Full Spectrum Far IR Sauna, 1–2 Person “FULL SPECTRUM INFRARED MODEL SAUNA FOR INDOOR USE ONLY 120VAC 15AMP Dedicated Circuit Required”… Documented · manual, p. 1 · 2026-09-28
Dynamic Saunas Heming Far IR Sauna, 2 Person, DYN-6225-02 …“Manual CARBON MODEL SAUNA SAUNA IS FOR INDOOR USE ONLY 120VAC 15AMP Dedicated Circuit Required”… Documented · manual, p. 1 · 2026-09-28
Dynamic Saunas Heming Far IR Sauna, 2 Person, DYN-6225-02 Elite …“Manual CARBON MODEL SAUNA SAUNA IS FOR INDOOR USE ONLY 120VAC 15AMP Dedicated Circuit Required”… Documented · manual, p. 1 · 2026-09-28
Dynamic Saunas Llumeneres Full Spectrum Far IR Sauna, 2 Person …“Electrical service: 120V/15amp plug & play”… Listed · manufacturer page · 2026-10-07
Dynamic Saunas Lucca Far IR Sauna, 2 Person, DYN-6215-05 …“Electrical service: 120V/15amp plug & play”… Listed · manufacturer page · 2026-10-07
Dynamic Saunas Lucca Far IR Sauna, 2 Person, DYN-6215-05 Elite …“WiFi Capability SAUNA IS FOR INDOOR USE ONLY 120VAC 15AMP Dedicated Circuit Required (DYN-6115-05/DYN-6215-05)”… Documented · manual, p. 1 · 2026-09-28
Dynamic Saunas Lugano Far IR Sauna, 3 Person, DYN-6336-02 …“Electrical service: Special Electrical 120 V/20 AMP Non GFCI Dedicated Receptacle and breaker”… Listed · manufacturer page · 2026-10-07
Dynamic Saunas Lugano Far IR Sauna, 3 Person, DYN-6336-02 Elite …“Electrical service: Special Electrical 120 V/20 AMP Non GFCI Dedicated Receptacle and breaker”… Listed · manufacturer page · 2026-10-07
Dynamic Saunas Lugano Full Spectrum IR Sauna, 3 Person “CARBON MODEL SAUNAS SAUNAS ARE FOR INDOOR USE ONLY 120VAC 20AMP Dedicated Circuit Required”… Documented · manual, p. 1 · 2026-09-28
Dynamic Saunas Madrid Limited Elite Far IR Sauna, 3 Person …“DYN-6310-04 - 120VAC 20AMP Dedicated Circuit Required”… Documented · manual, p. 1 · 2026-10-07
Dynamic Saunas Martin Full Spectrum Far IR Sauna, 1–2 Person …“Electrical service: 120V/15amp Non GFCI plug & play (Recommended Dedicated Outlet)”… Listed · manufacturer page · 2026-10-07
Dynamic Saunas Monaco Far IR Sauna, 6 Person “Electrical service: Special Electrical 2 separate dedicated 20 amp 120 volt outlets, two separate 20 amp breakers required”……“service: Special Electrical 2 separate dedicated 20 amp 120 volt outlets, two separate 20 amp breakers required Non GFCI”… Listed · manufacturer page · 2026-10-07Listed · manufacturer page · 2026-10-07
Dynamic Saunas San Marino, 2 Person …“– with WiFi Capability (Optional) FOR INDOOR USE ONLY 120VAC 15AMP Dedicated Circuit Required”… Documented · manual, p. 1 · 2026-10-07
Dynamic Saunas Santiago Far IR Sauna, 2 Person …“Electrical service: 120V/15amp Non GFCI plug & play (Recommended Dedicated Outlet)”… Listed · manufacturer page · 2026-10-07
Dynamic Saunas Santiago Full Spectrum IR Sauna, 2 Person …“Electrical service: 120V/15amp Non GFCI plug & play (Recommended Dedicated Outlet)”… Listed · manufacturer page · 2026-10-07
Dynamic Saunas Santorini Full Spectrum Far IR Sauna, 1–2 Person …“Electrical service: 120V/15amp Non GFCI plug & play (Recommended Dedicated Outlet)”… Listed · manufacturer page · 2026-10-07
Dynamic Saunas Serena Far IR Sauna, 2 Person …“Electrical service: 120V/15amp Non GFCI plug & play (Recommended Dedicated Outlet)”… Listed · manufacturer page · 2026-10-07
Dynamic Saunas Serena Full Spectrum Infrared Sauna, 2 Person …“Electrical service: 120V/15amp Non GFCI plug & play (Recommended Dedicated Outlet)”……“WiFi Capability (Optional) SAUNA IS FOR INDOOR USE ONLY 120VAC 15AMP Dedicated Circuit Required”… Listed · manufacturer page · 2026-10-07Documented · manual, p. 1 · 2026-09-28
Dynamic Saunas Toscana Far IR Sauna, 3 Person …“Electrical service: 120V/20amp dedicated receptacle (consult a certified electrician)”… Listed · manufacturer page · 2026-10-07
Dynamic Saunas Toscana Far IR Sauna, 3 Person, DYN-6315-05 Elite …“120VAC 20AMP Dedicated Circuit Required (DYN-6315-05)”… Documented · manual, p. 1 · 2026-09-28
Dynamic Saunas Veneto Far IR Sauna, 1–2 Person …“Electrical service: 120V/15amp plug & play”… Listed · manufacturer page · 2026-10-07
Dynamic Saunas Venice Far IR Sauna, 2 Person …“Electrical service: 120V/15amp Non GFCI plug & play (Recommended Dedicated Outlet)”… Listed · manufacturer page · 2026-10-07
Dynamic Saunas Venice Limited Elite Far IR Sauna, 2 Person …“DYN-6210-04 - 120VAC 15AMP Dedicated Circuit Required”… Documented · manual, p. 1 · 2026-10-07
Dynamic Saunas Venice, 2 Person …“DYN-6210-01 requires 120V 15 AMP DEDICATED CIRCUIT”… Documented · manual, p. 1 · 2026-09-28
Dynamic Saunas Vila Grande Full Spectrum Far IR Sauna, 4 Person …“Electrical service: 120V/20amp plug & play”… Listed · manufacturer page · 2026-10-07
Dynamic Saunas Vittoria Far IR Sauna, 2 Person, DYN-6220-01 …“MODEL SAUNAS - with WiFi Capability FOR INDOOR USE ONLY 120VAC 15AMP Dedicated Circuit Required”… Documented · manual, p. 1 · 2026-09-28
Dynamic Saunas Vittoria Far IR Sauna, 2 Person, DYN-6220-01 Elite …“MODEL SAUNAS - with WiFi Capability FOR INDOOR USE ONLY 120VAC 15AMP Dedicated Circuit Required”… Documented · manual, p. 1 · 2026-09-28
Finnmark Designs FD-1 Full-Spectrum Infrared Sauna, 1 Person …“Circuit Requirements: Dedicated 15A Circuit •”…Amperage stated, not described as a circuit: …“Power: 120V / 1450w / 15A”… Documented · manual, p. 5 · 2026-10-07Documented · manual, p. 35 · 2026-10-07
Golden Designs Catalonia Far IR Sauna, 8 Person …“Electrical Service: 240V / 30AMP”…“NEAR ZERO EMF INFRARED MODEL SAUNA FOR INDOOR USE ONLY 240V/30AMP DEDICATED CIRCUIT/RECEPTACLE REQUIRED”… Listed · manufacturer page · 2026-10-07Documented · manual, p. 1 · 2026-09-28
Golden Designs GDI-6996-02 Elite, 6 Person “Electrical Service: Special Electrical 2 separate dedicated 20 amp 120 volt outlets, two separate 20 amp breakers required.”… Listed · manufacturer page · 2026-10-07
Golden Designs Monaco Far IR Sauna, 6 Person “Electrical Service: Special Electrical 2 separate dedicated 20 amp 120 volt outlets, two separate 20 amp breakers required.”… Listed · manufacturer page · 2026-10-07
Golden Designs Reserve Edition Full Spectrum with Himalayan Salt Bar, 1 Person …“Electrical service: 120 V/15 AMP Non GFCI plug & play (Recommended Dedicated Outlet)”… Listed · manufacturer page · 2026-10-07
Golden Designs Reserve Edition Full Spectrum with Himalayan Salt Bar, 2 Person …“GDI-8020-03 FS - 120V/15AMP DEDICATED CIRCUIT REQUIRED”… Documented · manual, p. 1 · 2026-10-07
Golden Designs Reserve Edition Full Spectrum with Himalayan Salt Bar, 3 Person, GDI-8030-03 …“GDI-8030-03 FS - 120V/20AMP DEDICATED CIRCUIT REQUIRED”… Documented · manual, p. 1 · 2026-10-07
Golden Designs Reserve Edition GDI-8040-03, 4 Person …“GDI-8040-03 FS – TWO SEPARATE 120V/15AMP DEDICATED CIRCUITS REQUIRED”… Documented · manual, p. 1 · 2026-10-07
Golden Designs Reserve Edition GDI-8230-01, 3 Person …“Electrical service: Dual x 120v/15 AMP Non GFCI”… Listed · manufacturer page · 2026-10-07
Golden Designs Reserve Edition GDI-8260-01, 6 Person …“MODEL SAUNA SAUNA IS FOR INDOOR USE ONLY Two 120VAC 15AMP Separate Dedicated Circuits Required”… Documented · manual, p. 1 · 2026-09-28
Maxxus Alpine Dual Tech Far IR Sauna, 3 Person …“MX-J306-02S - 120VAC 20AMP Dedicated Circuits Required”… Documented · manual, p. 1 · 2026-09-28
Maxxus Aspen Dual Tech Far IR Sauna, 2 Person …“MX-J206-02S - 120VAC 15AMP Dedicated Circuit Required”… Documented · manual, p. 1 · 2026-09-28
Maxxus Bellevue Far IR Sauna, 3 Person, MX-J306-01 …“MX-J306-01 120VAC 20AMP Dedicated Circuit Required”… Documented · manual, p. 1 · 2026-09-28
Maxxus Bellevue Far IR Sauna, 3 Person, MX-J306-01 ZF …“MX-J306-01 120VAC 20AMP Dedicated Circuit Required”… Documented · manual, p. 1 · 2026-09-28
Maxxus Full Spectrum IR Sauna, 2 Person …“Electrical service: 120 V/15 AMP Non GFCI plug & play”… Listed · manufacturer page · 2026-10-07
Maxxus MX-K406-01 Hemlock, 4 Person …“MX-K406-01 - 120VAC 20AMP Dedicated Circuits Required”… Documented · manual, p. 1 · 2026-09-28
Maxxus Montilemar Far IR Sauna, 3 Person …“Electrical Service: Special Electical 120 V/20 AMP Non GFCI dedicated receptacle and breaker”… Listed · manufacturer page · 2026-10-07
Maxxus S-Line Far IR Sauna, 1 Person …“Electrical service: 120V/15 AMP Non GFCI plug & play”… Listed · manufacturer page · 2026-10-07
Maxxus S-Line Far IR Sauna, 2 Person …“Electrical service: 120V/15 AMP Non GFCI plug & play”… Listed · manufacturer page · 2026-10-07
Maxxus S-Line Far IR Sauna, 3 Person …“Electrical service: Special Electrical 120 V/20 AMP Non GFCI dedicated receptacle and breaker”… Listed · manufacturer page · 2026-10-07
Maxxus S-Line Full Spectrum IR Sauna, 2 Person …“Electrical service: 120V/15 AMP Non GFCI plug & play”… Listed · manufacturer page · 2026-10-07
Maxxus S-Line Full Spectrum IR Sauna, 3 Person …“Electrical service: Special Electrical 120 V/20 AMP Non GFCI dedicated receptacle and breaker”… Listed · manufacturer page · 2026-10-07
Maxxus Seattle Far IR Sauna, 2 Person, MX-J206-01 …“MX-J206-01 120VAC 15AMP Dedicated Circuit Required”… Documented · manual, p. 1 · 2026-09-28
Maxxus Seattle Far IR Sauna, 2 Person, MX-J206-01 ZF …“MX-J206-01 120VAC 15AMP Dedicated Circuit Required”… Documented · manual, p. 1 · 2026-09-28
Maxxus Toulose Far IR Sauna, 2 Person …“MX-K206-01 - 120VAC 15AMP Dedicated Circuit Required”… Documented · manual, p. 1 · 2026-09-28
Salus Element Full Spectrum Infrared Indoor Sauna, 2 Person …“Electrical service: 120V/15amp”… Listed · manufacturer page · 2026-09-27
Salus Element King Full Spectrum Infrared Indoor Sauna, 3 Person …“120V/20amp (consult a certified electrician to install 20 amp outlet and 20 amp breaker)”……“Electrical service: 120V/20amp (consult a certified electrician to install 20 amp outlet”… Listed · manufacturer page · 2026-09-27Listed · manufacturer page · 2026-09-27
Salus Elite Far Infrared Indoor Sauna, 6 Person …“SAUNA FOR INDOOR USE ONLY REQUIRES 2 SEPARATE DEDICATED 120V/20 AMP OUTLETS”… Documented · manual, p. 1 · 2026-09-27
Salus Glamour Far Infrared Indoor Sauna, 1 Person …“Electrical service: 120V/15amp”… Listed · manufacturer page · 2026-09-27
Salus Grand Element Full Spectrum Infrared Indoor Sauna, 4 Person …“Electrical service: 2 separate dedicated 15 amp 120 volt outlets, two separate 15 amp breakers required.(Please”… Listed · manufacturer page · 2026-09-27
Salus Grand Laurel Far Infrared Indoor Sauna, 3 Person …“Electrical service: 120V/20amp (please consult a certified electrician for”… Listed · manufacturer page · 2026-09-27
Salus Grand Retreat Full Spectrum Infrared Indoor Sauna, 6 Person “Carbon Model Sauna Sauna is for Indoor Use Only Two 120V/15AMP Dedicated Circuit”… Documented · manual, p. 1 · 2026-09-27
Salus Laurel Far Infrared Indoor Sauna, 1 Person …“Electrical service: 120V/15amp”… Listed · manufacturer page · 2026-09-27
Salus Luxen Far Infrared Indoor Sauna, 4 Person “MODEL SAUNA HEMLOCK WOOD MODEL with CARBON HEATERS 120VAC/20AMP Dedicated Circuits Required”… Documented · manual, p. 1 · 2026-09-27
Salus Majestic Far Infrared Indoor Sauna, 8 Person “INFRARED MODEL SAUNAS SAUNA IS FOR INDOOR USE ONLY REQUIRES 240V/30AMP DEDICATED CIRCUIT/ RECEPTACLE REQUIRED”… Documented · manual, p. 1 · 2026-09-27
Salus Nirvana Far Infrared Indoor Sauna, 2 Person “INFRARED MODEL SAUNA HEMLOCK WOOD SAUNA IS FOR INDOOR USE 120VAC 15AMP Dedicated Circuit Required”… Documented · manual, p. 1 · 2026-09-27
Salus Novalis Far Infrared Indoor Sauna, 2 Person “CARBON MODEL SAUNAS SAUNA IS FOR INDOOR USE ONLY 120VAC/15AMP Dedicated Circuit Required”… Documented · manual, p. 1 · 2026-09-27
Salus Paramount Far Infrared Indoor Sauna, 2 Person …“Electrical service: 120V/15amp”… Listed · manufacturer page · 2026-09-27
Salus Prana Far Infrared Indoor Sauna, 2 Person …“ULTRA LOW EMF CARBON MODEL SAUNA FOR INDOOR USE ONLY 120VAC/15AMP Dedicated Circuit Required”… Documented · manual, p. 1 · 2026-09-27
Salus Reprieve Full Spectrum Infrared Indoor Sauna, 2 Person …“Electrical service: 120V/15amp plug & play”… Listed · manufacturer page · 2026-09-27
Salus Uplift Full Spectrum Infrared Indoor Sauna, 3 Person …“Electrical service: 120V/20amp dedicated receptacle (consult a certified electrician)”… Listed · manufacturer page · 2026-09-27
Sun Home Eclipse Indoor Red Light & Full-Spectrum Infrared Sauna, 2 Person …“30A twist- locking receptacle is normally protected by a 30A GFCI circuit breaker rather than a GFCI receptacle, ask”……“The Eclipse 2 requires a dedicated, GFCI-protected 120V, 30A circuit with a NEMA L5-30R twist- locking receptacle, installed”……“GFCI protection is required: the dedicated circuit must be GFCI protected.”… Documented · manual, p. 8 · 2026-09-28Documented · manual, p. 8 · 2026-09-28Documented · manual, p. 8 · 2026-09-28
Sun Home Eclipse Indoor Red Light & Full-Spectrum Infrared Sauna, 4 Person …“The dedicated 240V receptacle must be installed by a licensed electrician”…“Rated Current 22A Circuit Dedicated 240V, 30A circuit Plug NEMA L6-30P (twist-locking) Receptacle NEMA L6-30R (twist-locking)”……“The Eclipse 4 requires a dedicated 240V, 30A circuit with a NEMA L6-30R twist-locking receptacle, installed”… Documented · manual, p. 5 · 2026-09-28Documented · manual, p. 7 · 2026-09-28Documented · manual, p. 8 · 2026-09-28
Sun Home Equinox Indoor Full-Spectrum Infrared Sauna, 2 Person …“Up to 165°F ELECTRICAL RATED ELECTRICAL 120V / 1,880W / 15.67A PLUG NEMA 5-20P RECEPTACLE NEMA 5-20R”……“ELECTRICAL RATED ELECTRICAL 120V / 1,880W / 15.67A PLUG NEMA 5-20P RECEPTACLE NEMA 5-20R POWER CORD 10 ft ·”……“Outlet Electrical Dedicated 20 Amp Circuit Outlet NEMA 5-20”… Documented · manual, p. 1 · 2026-09-28Documented · manual, p. 1 · 2026-09-28Listed · manufacturer page · 2026-09-28
Sun Home Equinox Indoor Full-Spectrum Infrared Sauna, 3 Person …“Up to 165°F ELECTRICAL RATED ELECTRICAL 120V / 2,250W / 20A PLUG NEMA 5-20P RECEPTACLE NEMA 5-20R POWER CORD 10 ft ·”……“Outlet Electrical Dedicated 20 Amp Circuit Outlet NEMA 5-20”… Documented · manual, p. 1 · 2026-09-28Listed · manufacturer page · 2026-09-28
Sun Home Luminar Outdoor Full-Spectrum Infrared Sauna, 2 Person …“at least 1,500 lb (680 kg) Capacity 2 persons Circuit 240V, 20A dedicated circuit with GFCI protection”……“The Luminar 2 requires a dedicated 240V 20A circuit with a NEMA L6-20R twist-locking outlet, protected by a”… Documented · manual, p. 6 · 2026-09-28Documented · manual, p. 7 · 2026-09-28
Sun Home Luminar Outdoor Full-Spectrum Infrared Sauna, 5 Person …“stainless steel exterior roof; tempered glass Circuit 240V, 30A dedicated circuit with GFCI protection”……“The Luminar 5 requires a dedicated 240V 30A circuit with a NEMA L6-30R twist-locking outlet, protected by a”… Documented · manual, p. 7 · 2026-09-28Documented · manual, p. 7 · 2026-09-28
Sun Home Solstice Indoor Infrared Sauna, 1 Person …“Outlet Electrical Dedicated 20 Amp Circuit Outlet NEMA 5-20”…Amperage stated, not described as a circuit: “OPERATING TEMPERATURE 130–140°F ELECTRICAL RATED ELECTRICAL 120V / 1,350W / 20A PLUG NEMA 5-20P POWER CORD 10 ft ·”… Documented · manual, p. 1 · 2026-09-28Listed · manufacturer page · 2026-09-28
Sun Home Solstice Indoor Infrared Sauna, 2 Person …“Outlet Electrical Dedicated 20 Amp Circuit Outlet NEMA 5-20”…Amperage stated, not described as a circuit: “OPERATING TEMPERATURE 130–140°F ELECTRICAL RATED ELECTRICAL 120V / 2,006W / 20A PLUG NEMA 5-20P POWER CORD 10 ft ·”… Documented · manual, p. 1 · 2026-09-28Listed · manufacturer page · 2026-09-28
Sun Home Solstice Indoor Infrared Sauna, 3 Person …“Outlet Electrical Dedicated 20 Amp Circuit Outlet NEMA 5-20”…Amperage stated, not described as a circuit: “OPERATING TEMPERATURE 130–140°F ELECTRICAL RATED ELECTRICAL 120V / 2,250W / 20A PLUG NEMA 5-20P POWER CORD 10 ft ·”… Documented · manual, p. 1 · 2026-09-28Listed · manufacturer page · 2026-09-28
Sun Home Solstice Indoor Infrared Sauna, 4 Person …“130–140°F ELECTRICAL RATED ELECTRICAL 240V / 2,750W / 20A PLUG NEMA 6-20P RECEPTACLE NEMA 6-20R POWER CORD 10 ft ·”…“OPERATING TEMPERATURE 130–140°F ELECTRICAL RATED ELECTRICAL 240V / 2,750W / 20A PLUG NEMA 6-20P RECEPTACLE NEMA 6-20R”……“Outlet Electrical Dedicated 20 Amp Circuit Outlet NEMA 6-20”… Documented · manual, p. 1 · 2026-09-28Documented · manual, p. 1 · 2026-09-28Listed · manufacturer page · 2026-09-28

Local electrical codes vary. The manufacturer's installation manual and your local code govern, and a licensed electrician sizes and installs the circuit.